Skip to main content

Our Products

Chroma Nexus Data Logger and Nexus Cloud SAAS — purpose-built for emission compliance and industrial analytics.

Chroma Nexus Data Logger — front view with terminal blocks and status LEDs
New
Flagship product

Chroma Nexus Data Logger

Built for emission compliance — industrial AI on the edge.

A DIN-rail mounted edge gateway purpose-built for OCEMS reporting. CPCB 2025 API ready out of the box, with AES-256 encrypted payloads. Integrates with any Modbus, 4-20 mA or TCP/IP analyser and pushes to Central, State and customer cloud servers in parallel.

CPCB 2025 API ready AES-256 encrypted DIN-rail mountable OCEMS compliant
What's inside

Engineered for every part of the stack.

From the analyser terminal to the State PCB API — Nexus handles every hop, with audit-grade reliability.

Designed for OCEMS Compliance

  • CPCB 2025 API ready with AES-256 encryption
  • All State PCB APIs and payload formats supported
  • Parallel push to multiple servers and protocols
  • Network failure handling with server backfill

Versatile Instrument Connectivity

  • Modbus RS485/RTU & Modbus TCP/IP
  • 6-channel 4-20 mA analog inputs
  • 6-channel digital inputs & outputs
  • TCP/IP parsing for WTW / Xylem

High-Performance Hardware

  • Quad-core ARM Cortex-A76 (64-bit) @ 2.4 GHz — industrial Raspberry Pi compute
  • 2 GB LPDDR4X SDRAM (expandable)
  • 16 GB industrial SD storage (expandable to 1 TB)
  • 4G/LTE + WiFi + Gigabit Ethernet connectivity

ChromaTech Firmware Stack

  • MQTT, REST API & FTP with TLS/SSL security
  • Flexible JSON and text payload generator · CSV export
  • IP-based configuration with integrated web server
  • Device APIs for remote configuration via MQTT
Parameters supported

Measure the parameters your PCB reports require.

Nexus reads from any compatible emission, stack and water analyser — and pushes the values your State and Central PCB integrations expect.

BOD COD TSS pH Chlorine PM Flow SO₂ SOx NOx NO CO
Optional add-ons

Extend Nexus for your plant.

Calibration workflows, State PCB integrations and hardware add-ons — available on the same chassis.

Optional

State PCB API support

Haryana, MP, Maharashtra, Tamil Nadu and Telangana out of the box. Other state PCBs available on request.

Optional

Analyser Calibration

Calibration flow over Modbus write with integrated CPCB reporting — keep the audit chain intact during calibration cycles.

Optional

DI/DO Calibration Module

Add-on module — Modbus to 6-channel DI (potential-free input) and 6-channel DO (potential-free relay, max 5 A @ 230 VAC).

Companion platform

Nexus Cloud SAAS

The cloud half of the Nexus stack. Sign in to see live readings, historical telemetry, threshold alerts and the CPCB push results for every Chroma Nexus on your plant.

  • Live sensor readings refreshing in real time, per device
  • Online status with last-heartbeat indicator on every device
  • Hourly history and 30-second calibration samples for any date
  • Custom date ranges for historical telemetry analysis
  • Threshold alerts with unresolved counts and full event history
  • CPCB push results with 24-hour sparklines per integration
nexuscloud.boldally.in
Nexus Cloud dashboard — live readings, hourly history and integration responses for a Chroma Nexus device
Technical data sheet

Specifications

Full reference for procurement, integration and commissioning. Need a printable PDF version? Ask our team.

Power & Form Factor

Rated input supply
12V / 24V DC
Mounting
DIN rail and wall mounting
Dimensions
100 mm (W) × 120 mm (H) × 70 mm (D)
Enclosure
ABS plastic · IP30 (IP67 optional for outdoor)
Terminals
5 mm pluggable terminal jacks
Operating temperature
0 °C to 60 °C
Storage temperature
-2 °C to 80 °C
Humidity
Upto 85% (non-condensing)
Weight
300 g (approx)

Compute & Memory

Processor
Quad-core eARM Cortex-A76 (64-bit) @ 2.4 GHz
RAM
2 GB LPDDR4X (or higher)
Storage
16 GB industrial SD card (expandable to 1 TB)
RTC
Inbuilt accurate RTC with battery · NTP sync
Display
OLED screen for status and configuration

Communication & I/O

Ethernet
Gigabit (1000 Mbps)
4G / LTE
LTE Cat 1 · backward compatible with 2G/GPRS
WiFi
Built-in WiFi
RS-485 ports
Two ports · configurable Modbus master/slave
Analog inputs
6 channels · 0-20 mA / 4-20 mA
Digital I/O
6 digital input · 6 digital output
USB ports
2× USB 3.0 · 2× USB 2.0
Optional add-on
4× USB Ethernet 1 (secondary)

OCEMS & API

CPCB API
CPCB 2025 API push with AES-256 encryption
State PCB APIs
Haryana · MP · Maharashtra · Tamil Nadu · Telangana (others on request)
Cloud protocols
MQTT · REST · HTTP · FTP over SSL/TLS
Analyser calibration
Calibration flow over Modbus write with CPCB integration
DI/DO calibration
Add-on module · Modbus to 6-channel DI/DO (potential-free relays, max 5 A @ 230 VAC)
Modbus capacity
Upto 500 tags · 24 Modbus slaves per channel
Data logger
Flexible CSV files (daily / monthly / yearly) · IP based device access
Part numbers

Choose your Nexus.

Two variants. Same firmware stack, same OCEMS compliance — sized to plant scale.

Recommended

Nexus 400

Part · CT400
Ethernet
Gigabit
4G / LTE
4G/LTE (India · Asia)
RAM
2 GB (upto 8 GB available)
Storage
32 GB
I/O bus
USB · LAN
Request a quote for Nexus 400

Want to evaluate Chroma Nexus on your plant?

Tell us about the analysers you need to integrate and we will scope the right Nexus variant and Cloud subscription for you.

Anil Kumar now
Hi, want to know about our products or services?